2-Channel model with automatic sensor identification Allows for connections of pH/ORP/ion/conductivity/dissolved O2 sensors to either channel 0.01/0.001 pH display switchable Large color graphic LCD display JP16 (The Japanese Pharmacopoeia 16th edition) conformity and stable electric conductivity measurement USB (Host) and LAN equipped as standard specification External printer connectable Multiple sample measuring capability (turntable connection) Data storage up to 300 points Measurement items pH, ORP, electric conductivity, resistivity, salinity, ion, temperature, DO, saturate
● Immersion type of sensor which is convenient for turbidity measurement in fields ● Reliability of low-concentration measurement has been improved (repeatability within the range of ±0.5NTU) ● Power-saving design; rechargeable battery adaptable ● Waterproof design (IP67: 1m depth, up to 30mins) Meas. range 0.0 - 80.0 NTU (mg/L) 0 - 800 NTU (mg/L) Switch modes: auto/manual
Alternative model to existing controller such as U-22, U-02, etc. Same panel cut size, easy installation Interactive input interface supports auto-calibration and multi-stream Auto-calibration, self-diagnostic, remote control, communication function equipped
DO-31P -1000 point data memory -LCD display for all parameters -Salinity and atmosphereic pressure correction -Data print-out capability -Automatic Time interval Measurement -Water proof housing -Data hold function and auto power off
The cleaning process done by two filters alternately allows for continuous supply of sample Filtration rate 1 - 6 L/min (Varies from sample turbidity)
The integrated oxidation & titration design and the sequence control function simplified operations Smaller waste solution (lower than 10mL per measurement) Real time display of sequence and titration curve Meas. range 0 - 20.0/40.0/100/200/400/1000 mg/L
Compact diecast aluminum enclosure ExiallCT4 (combined with a Zener Barrier) explosion-proof and IP65 conformed enclosure Easy calibration done with standard solution Auto-detection of electrodes deterioration Alterable output range Meas. range SHBM-161: pH; -1 - 15 SHBM-163: ORP; -2000 - +2000 mV
Oil film is detected by measuring differences of the amount of laser reflectance of oil and water With improvements on light source scanning and signal processing, influences occurred in broad water surfaces such as fluctuation, waviness and suspended solids have been reduced effectively Contact-free and easy maintenance Detectable range 0.3 - 3 m